News |

Flexible air conditioning solution for modular Data Centers

Outdoor air conditioning container combines energy efficiency with short installation times: The 20-foot air conditioning containers from the STULZ CyberCon series are available with a cooling capacity of 243 kW per unit and offer state-of-the-art energy-saving technology such as Free Cooling function, EC fans and adiabatic cooling.

 

Hamburg, 30.05.2015 – With the CyberCon series, STULZ is introducing a flexible outdoor air conditioning solution for Data Centers in a container format. These precision air conditioning systems are available as DX or CW versions and are delivered pre-installed in standardized 20-foot ISO containers. For the air conditioning of 40-foot Data Centers, two STULZ CyberCon containers can be combined as an end-to-end installation. The systems, which have a vertical air outlet, are specially designed for container Data Centers, and can simply be mounted on a container module with the server equipment that needs cooling. All connections take place on the air side only. The standardized all-in-one design of the CyberCon series meets all the requirements of mobile Data Centers. As server capacities grow, thanks to the STULZ E2 control system further air conditioning containers can easily be added and integrated in the building services management system (Modbus, BacNet). This enables even complex redundancy strategies – for multi-tier Data Centers, for example – to be achieved without problem. What's more, all models are available as dual fluid versions with two independent refrigeration systems, based either on the direct evaporator DX/DX system, the liquid cooled CW/CW System, or the DX/CW system. With two independent cooling sides, redundancy is already integrated in the unit.  

Modular container system CyberCon

The STULZ CyberCon series can be further enhanced by optional energy-saving technologies, such as compressors capable of working in partial load mode, EC fans, and Direct Free Cooling, adiabatic cooling and humidification modules. The combination of Free Cooling and adiabatic cooling enables significant energy savings of up to 80%, depending on geographical location and ambient parameters. This means that the STULZ CyberCon can satisfy even the most stringent efficiency requirements. 

More information on CyberCon

 

Press Contact

Please choose your contact

  • Press Contact

    For press information please contact:

    STULZ México S.A. de C.V.

    Av. Santa Fe No. 170 German Centre

    Oficina 2-2-08 Col. Lomas de Santa Fe

    Delegación Alvaro Obregón

    01210 Cd. De México

    Tel. +52 (55) 5292 8596

    marketing@stulz.com.mx

More contact options
To top